marine door
Marine steel weathertight door with single leaf
DATE:2014-08-07 09:37:38

Application

used for the doorway of superstructure above freeboard deck or deck house to meet ISO6042-1980

Class and used place

Class

Applicable Position

A

Front bulkhead of the first superstructure above freeboard deck(in the range 0.1-0.7L forward after perpendicular)

B

Front bulkhead of the second superstructure above freeboard deck(in the range 0.1-0.7L forward after perpendicular), and the aft bulkhead & side wall of the first superstructure.

C

Front bulkhead of the third superstructure above freeboard deck(in the range 0.2-0.6L forward after perpendicular),and the aft bulkhead & side wall of the second superstructure.

D

Front bulkhead of the fourth superstructure above freeboard deckand the aft bulkhead & side wall of the third superstructure.

Type and Standard

Type Name standard
AF Class A square angle 1050       1260         1460         1475
AY Class A cycle angle (1000*500) (1200*600)   (1400*600)   (1400*750)
BF Class B square angle 1050       1260         1460         1475
BY Class B cycle angle (1000*500) (1200*600)   (1400*600)   (1400*750)
CF Class C square angle 1490          1660       1675        1690
CY Class C cycle angle (1400*900) (1600*600)   (1600*750)   (1600*900)
DF Class D square angle 1050        1260         1460         1475
(1000*500) (1200*600)   (1400*600)   (1400*750)
1490        1660         1675         1690
(1400*900) (1600*600)   (1600*750)   (1600*900)
1860        1875         1890
(1800*600) (1800*750)   (1800*900)
DY Class D cycle angle
Remark: diameter of  250 fixed light available for class C&D, code as G.

Section

Leaf of thickness Shelter size Frame high Frame material
8 50*6 32 L100*63*10 cutting manufacture
6 32*4 34
4 36 L100*63*8 cutting manufacture

Standard and Parameter

Standard Clear size (mm*mm) Leaf size(mm*mm) Opening size of wall(mm*mm*mm) Leaf thickness QTY of clips Quality/kg / Remarks
A,B C D
AF\BF\CF\DF AY\BY\CY\DY Shipyard L A\B\C D Leaf thickness
80 >80 80 >80 / 4 6 8
1050 1000*500 1055*555 1100*600 R80 1100*600 R150 6 / 4 / 4 6 3 22 30 /
1260 1200*600 1255*655 1300*700 R80 1300*700 R150 6 / 4 / 4 6 3 30 41 /
1460 1400*600 1455*655 1500*700 R80 1500*700 R150 6 8 4 6 4 6 3 35 55 77
1475 1400*750 1455*805 1500*850 R80 1500*850 R150 6 8 4 6 4 6 3 45 66 92
1490 1400*900 1455*955 1500*1000 R80 1500*1000 R150 / 8 / 6 6 8 4 60 77 107
1660 1600*600 1655*655 1700*700 R80 1700*700 R150 / 8 / 6 6 6 3 / 63 87
1675 1600*750 1655*805 1700*850 R80 1700*850 R150 / 8 / 6 6 6 3 / 75 104
1690 1600*900 1655*955 1700*1000 R80 1700*1000 R150 / 8 / 6 6 8 4 / 88 121
1860 1800*600 1855*655 1900*700 R80 1900*700 R150 / / / / 6 / 3 / 70 /
1875 1800*750 1855*805 1900*850 R80 1900*850 R150 / / / / 6 / 3 / 76 /
1890 1800*900 1855*955 1900*1000 R80 1900*1000 R150 / / / / 6 / 4 /